ПвВГнг(А)-FRLS – (PvVGng(A)-FRLS) – Russian analogue of NHXYu Fire Resistance Low Smoke FE180 MICA

PvVGng(A)-FRLS

Description Add to order

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric energy in stationary electric installations, for installation in cable structures, buildings and underground structures, including flammable and explosive areas, for supply chains of the equipment, which operates in fire.

The cables of types PvPGEng(A)-FRLS and PvBPng(A)- FRLS of rated voltage 3 kV are used in DC voltage units and they are available in single-core modification.

The class of fire hazard of the cables according to GOST 31565-2012 П1б.1.2.2.2.

 

TECHNICAL DATA

Nominal voltage, kV – 0.66, 1 or 3

Ambient temperature during cable operation, 0C - from -50 to +50

Resistant with a relative humidity up to 98% at ambient temperature, degree Celsius, up to +35

Minimum bending radius, diameters of cable:

for single-wire – 10

for multi-wire – 7.5

Service life, years, not less: 30

Flame retardant at group installation in bunches on category: А

Equivalent toxicity index, g/m3 , more than: 40

Fire resistance of the cable, minutes, not less than: 180

 

STRUCTURE

Conductor

Copper, single-wire or multi-wire of the 1st or 2nd classes according to GOST 22483-2012, of the cross-section for 0.66 kV – 1.5 – 50 mm2 ;

for 1 kV – 1.5 – 240 mm2, single-wire – 50-630 мм2;

for 3 kV – 240 – 360 mm2.

Thermal barrier

The lapping with mica tapes.

Insulation

Cross-linked, halogen free, polymer composition.

Screen for single-wire cables of nominal voltage 3kV:

It is made of copper tapes or copper wires and a copper tape overlaid spirally.

Core arrangement

Insulated conductors of multi-core cables on 0.66 and 1kV are twisted in a cable core.

The cables have got distinctive markings of insulated cores: color or digital.

Inner sheath or separating layer (for armored cables on voltage 3kV)

It is made by extrusion with filling with the halogen free polymer compositions.

Cable armoring

For cables of types PvBShvng(A)-FRLS is laid helically with two steel, galvanized tapes.

It is possible to lay the PET-tapes by winding or longitudinally over the armor.

Cable sheath or jacket

PVC-compound of low fire hazard.

The cables are designed for transmission and distribution of electric energy in stationary electric installations, for installation in cable structures, buildings and underground structures, including flammable and explosive areas, for supply chains of the equipment, which operates in fire.

The cables of types PvPGEng(A)-FRLS and PvBPng(A)- FRLS of rated voltage 3 kV are used in DC voltage units and they are available in single-core modification.

The class of fire hazard of the cables according to GOST 31565-2012 П1б.1.2.2.2.

Nominal voltage, kV – 0.66, 1 or 3

Ambient temperature during cable operation, 0C - from -50 to +50

Resistant with a relative humidity up to 98% at ambient temperature, degree Celsius, up to +35

Minimum bending radius, diameters of cable:

for single-wire – 10

for multi-wire – 7.5

Service life, years, not less: 30

Flame retardant at group installation in bunches on category: А

Equivalent toxicity index, g/m3 , more than: 40

Fire resistance of the cable, minutes, not less than: 180

Conductor

Copper, single-wire or multi-wire of the 1st or 2nd classes according to GOST 22483-2012, of the cross-section for 0.66 kV – 1.5 – 50 mm2 ;

for 1 kV – 1.5 – 240 mm2, single-wire – 50-630 мм2;

for 3 kV – 240 – 360 mm2.

Thermal barrier

The lapping with mica tapes.

Insulation

Cross-linked, halogen free, polymer composition.

Screen for single-wire cables of nominal voltage 3kV:

It is made of copper tapes or copper wires and a copper tape overlaid spirally.

Core arrangement

Insulated conductors of multi-core cables on 0.66 and 1kV are twisted in a cable core.

The cables have got distinctive markings of insulated cores: color or digital.

Inner sheath or separating layer (for armored cables on voltage 3kV)

It is made by extrusion with filling with the halogen free polymer compositions.

Cable armoring

For cables of types PvBShvng(A)-FRLS is laid helically with two steel, galvanized tapes.

It is possible to lay the PET-tapes by winding or longitudinally over the armor.

Cable sheath or jacket

PVC-compound of low fire hazard.

Number and nominal cross-section of conductors (mm2) External diameter of cable, mm Weight, kg
PvVGng(A)-FRLS 3х1,5-0,66 13,6 289
km
PvVGng(A)-FRLS 3х2,5-0,66 14,4 344
km
PvVGng(A)-FRLS 3х4-0,66 15,4 418
km
PvVGng(A)-FRLS 3х6-0,66 16,5 510
km
PvVGng(A)-FRLS 3х10-0,66 18,3 680
km
PvVGng(A)-FRLS 3х16-0,66   20,3 919
km
PvVGng(A)-FRLS 3х25-0,66   25,5 1420
km
PvVGng(A)-FRLS 3х35-0,66   28 1810
km
PvVGng(A)-FRLS 3х50-0,66   27,5 2019
km
PvVGng(A)-FRLS 4х1,5-0,66 14,5 325
km
PvVGng(A)-FRLS 4х2,5-0,66 15,5 392
km
PvVGng(A)-FRLS 4х4-0,66 16,6 483
km
PvVGng(A)-FRLS 4х6-0,66 17,9 596
km
PvVGng(A)-FRLS 4х10-0,66 19,8 808
km
PvVGng(A)-FRLS 4х16-0,66   22,1 1106
km
PvVGng(A)-FRLS 4х25-0,66   27,9 1713
km
PvVGng(A)-FRLS 4х35-0,66   30,8 2218
km
PvVGng(A)-FRLS 4х50-0,66   30,5 2604
km
PvVGng(A)-FRLS 5х1,5-0,66 15,6 359
km
PvVGng(A)-FRLS 5х2,5-0,66 16,7 436
km
PvVGng(A)-FRLS 5х4-0,66 18 543
km
PvVGng(A)-FRLS 5х6-0,66 19,3 675
km
PvVGng(A)-FRLS 5х10-0,66 21,5 923
km
PvVGng(A)-FRLS 5х16-0,66 24,5 1302
km
PvVGng(A)-FRLS 5х25-0,66   30,7 1988
km
PvVGng(A)-FRLS 5х35-0,66   34,2 2603
km
PvVGng(A)-FRLS 5х50-0,66 34 3218
km
Number and nominal cross-section of conductors (mm2) External diameter of cable, mm Weight, kg
PvVGng(A)-FRLS 1х50-1 17,6 764
km
PvVGng(A)-FRLS 1х70-1 18,6 971
km
PvVGng(A)-FRLS 1х95-1 20,2 1234
km
PvVGng(A)-FRLS 1х120-1 21,9 1507
km
PvVGng(A)-FRLS 1х150-1 24,3 1868
km
PvVGng(A)-FRLS 1х185-1 26,3 2252
km
PvVGng(A)-FRLS 1х240-1 28,8 2823
km
PvVGng(A)-FRLS 1х300-1 31,7 3495
km
PvVGng(A)-FRLS 1х400-1 35,5 4545
km
PvVGng(A)-FRLS 1х500-1 38,7 5572
km
PvVGng(A)-FRLS 1х625/630-1 42,9 6966
km
PvVGng(A)-FRLS 3х1,5-1 14 303
km
PvVGng(A)-FRLS 3х2,5-1 14,9 359
km
PvVGng(A)-FRLS 3х4-1 15,9 435
km
PvVGng(A)-FRLS 3х6-1 17 527
km
PvVGng(A)-FRLS 3х10-1 18,7 699
km
PvVGng(A)-FRLS 3х16-1  20,7 939
km
PvVGng(A)-FRLS 3х25-1  26 1444
km
PvVGng(A)-FRLS 3х35-1  28,4 1836
km
PvVGng(A)-FRLS 3х50-1  27,3 2025
km
PvVGng(A)-FRLS 3х70-1 30,4 2691
km
PvVGng(A)-FRLS 3х95-1 33,1 3491
km
PvVGng(A)-FRLS 3х120-1 36,1 4305
km
PvVGng(A)-FRLS 3х150-1 39,6 5313
km
PvVGng(A)-FRLS 3х185-1 43,6 6508
km
PvVGng(A)-FRLS 3х240-1 48,1 8235
km
PvVGng(A)-FRLS 4х1,5-1 15 342
km
PvVGng(A)-FRLS 4х2,5-1 16 409
km
PvVGng(A)-FRLS 4х4-1 17,1 502
km
PvVGng(A)-FRLS 4х6-1 18,3 616
km
PvVGng(A)-FRLS 4х10-1 20,3 829
km
PvVGng(A)-FRLS 4х16-1  22,6 1129
km
PvVGng(A)-FRLS 4х25-1  28,4 1740
km
PvVGng(A)-FRLS 4х35-1  31,7 2284
km
PvVGng(A)-FRLS 4х50-1  30,3 2612
km
PvVGng(A)-FRLS 4х70-1 34,2 3518
km
PvVGng(A)-FRLS 4х95-1 37,6 4564
km
PvVGng(A)-FRLS 4х120-1 41 5641
km
PvVGng(A)-FRLS 4х150-1 45,5 7024
km
PvVGng(A)-FRLS 4х185-1 49,6 8539
km
PvVGng(A)-FRLS 4х240-1 55,4 10924
km
PvVGng(A)-FRLS 5х1,5-1 16,1 376
km
PvVGng(A)-FRLS 5х2,5-1 17,2 454
km
PvVGng(A)-FRLS 5х4-1 18,5 561
km
PvVGng(A)-FRLS 5х6-1 19,9 694
km
PvVGng(A)-FRLS 5х10-1 22 944
km
PvVGng(A)-FRLS 5х16-1 25 1326
km
PvVGng(A)-FRLS 5х25-1  31,7 2050
km
PvVGng(A)-FRLS 5х35-1  34,9 2650
km
PvVGng(A)-FRLS 5х50-1 33,8 3229
km
PvVGng(A)-FRLS 5х70-1 37,8 4326
km
PvVGng(A)-FRLS 5х95-1 41,8 5629
km
PvVGng(A)-FRLS 5х120-1 46 7021
km
PvVGng(A)-FRLS 5х150-1 50,4 8652
km
PvVGng(A)-FRLS 5х185-1 55,9 10665
km
PvVGng(A)-FRLS 5х240-1 61,6 13488
km