ПвВнг(А)-FRLS – (PvVng(A)-FRLS) – Russian analogue of N2XY Fire Resistance Low Smoke FE180 MICA

PvVng(A)-FRLS

Description Add to order

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power in networks on the nominal alternating voltage 1kV and frequency 50 Hz.

The cables are used for fixed installation of cable inside and outside of hermetic area of nuclear power stations. The cables are designed for use in the systems of nuclear power stations of class 2 and 3 according to classification of ОПБ 88/97 (ПНАЭ Г-01-011).

The class of fire hazard of the cables according to GOST 31565 for cables П1б.1.2.2.2.

Fire resistance of the cables should be not less than 180 min (FE180).

STRUCTURE

Conductor

Copper, single-wire or multi-wire core, of circular or sector-shaped form, of the 1 or 2 class according to GOST 22483.

Thermal barrier for CCC (current-carrying conductor)

The lapping with two mica tapes.

Insulation

XLPE (color coded conductor).

Core arrangement

Insulated conductors of multi-core cables are twisted in a cable core.

Inner sheath

PVC-compound of low fire hazard.

Lapping

For cables with the conductors of cross-section 50 mm2 and more is made of one fiber glass tape or mica tape.

Over sheath

It is made by filling of outer gaps between the insulated conductors with PVC-compound of low fire hazard.

Number of conductors, nominal cross-section (mm2) Outside diameter, mm Calculated weight of cable, kg/km The volume of the fuel mass, l / km
PvVng(A)-FRLS 1x1,5 10,7 163 89
m
PvVng(A)-FRLS 1x2,5 11,1 182 95
m
PvVng(A)-FRLS 1x4 11,6 206 101
m
PvVng(A)-FRLS 1x6 12,1 236 108
m
PvVng(A)-FRLS 1x10 12,9 291 119
m
PvVng(A)-FRLS 1x16 13,8 367 132
m
PvVng(A)-FRLS 1x25 16,1 507 168
m
PvVng(A)-FRLS 1x35 17,2 625 184
m
PvVng(A)-FRLS 1x50 19,6 825 215
m
PvVng(A)-FRLS 1x70 20,6 1033 233
m
PvVng(A)-FRLS 1x95 22,2 1299 256
m
PvVng(A)-FRLS 1x120 24,3 1598 303
m
PvVng(A)-FRLS 1x150 26,3 1934 346
m
PvVng(A)-FRLS 1x185 28,5 2332 400
m
PvVng(A)-FRLS 1x240 31 2904 449
m
PvVng(A)-FRLS 3x1,5 15,2 338 175
m
PvVng(A)-FRLS 3x2,5 16,1 395 192
m
PvVng(A)-FRLS 3х4 17,1 472 213
m
PvVng(A)-FRLS 3x6 18,2 567 235
m
PvVng(A)-FRLS 3x10 19,9 742 272
m
PvVng(A)-FRLS 3x16 21,9 986 318
m
PvVng(A)-FRLS 3x25 27,2 1491 470
m
PvVng(A)-FRLS 3x35 29,8 1905 549
m
PvVng(A)-FRLS 3x50 29,5 2099 432
m
PvVng(A)-FRLS 3x70 32,4 2745 498
m
PvVng(A)-FRLS 3x95 35,1 3541 568
m
PvVng(A)-FRLS 3x120 37,9 4327 638
m
PvVng(A)-FRLS 3x150 41,6 5342 772
m
PvVng(A)-FRLS 3x185 45,6 6507 922
m
PvVng(A)-FRLS 3x240 50,3 8250 1081
m
PvVng(A)-FRLS 4x1,5 16,2 373 189
m
PvVng(A)-FRLS 4x2,5 17,2 442 208
m
PvVng(A)-FRLS 4x4 18,3 535 230
m
PvVng(A)-FRLS 4x6 19,5 651 254
m
PvVng(A)-FRLS 4x10 21,5 866 294
m
PvVng(A)-FRLS 4x16 23,8 1169 343
m
PvVng(A)-FRLS 4x25 29,8 1793 517
m
PvVng(A)-FRLS 4x35 32,5 2286 591
m
PvVng(A)-FRLS 4x50 32,3 2664 500
m
PvVng(A)-FRLS 4x70 36,2 3557 608
m
PvVng(A)-FRLS 4x95 39,8 4629 703
m
PvVng(A)-FRLS 4x120 43 5673 795
m
PvVng(A)-FRLS 4x150 47,3 6996 961
m
PvVng(A)-FRLS 4x185 51,8 8538 1148
m
PvVng(A)-FRLS 4x240 57,2 10829 1348
m
PvVng(A)-FRLS 5x1,5 17,3 404 201
m
PvVng(A)-FRLS 5x2,5 18,4 482 220
m
PvVng(A)-FRLS 5x4 19,7 590 243
m
PvVng(A)-FRLS 5x6 21,1 723 267
m
PvVng(A)-FRLS 5x10 23,2 973 307
m
PvVng(A)-FRLS 5x16 26,2 1355 372
m
PvVng(A)-FRLS 5x25 32,5 2029 531
m
PvVng(A)-FRLS 5x35 35,9 2641 624
m
PvVng(A)-FRLS 5x50 35,8 3272 595
m
PvVng(A)-FRLS 5x70 40 4384 723
m
PvVng(A)-FRLS 5x95 43,8 5662 809
m
PvVng(A)-FRLS 5x120 47,8 7006 948
m
PvVng(A)-FRLS 5x150 52,6 8659 1150
m
PvVng(A)-FRLS 5x185 57,7 10560 1376
m
PvVng(A)-FRLS 5x240 63,4 13342 1576
m