ППГнг(А)-FRHF (PPGng(A)-FRHF) – Russian analogue of NHXH FE180/E90 MICA

PPGng(A)-FRHF

Description Add to order

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric power and electric signals in stationary electric units on the nominal alternating voltage 0.66 and 1kV and frequency 50 Hz.

The cables are used for group installation of cable power lines of safety systems, wiring circuits of fire safety, wiring circuits of the surgical departments of hospitals, circuits of emergency electric power of equipment, functioning in case of fire, in the absence of danger of mechanical damage during operation.

The cable is manufactured for general application and application at nuclear power plants (NPP) outside the hermetic area in the systems NPP of class 2 according to classification ОПБ 88/97 (ПНАЭ Г-01-011).

The class of fire hazard of the cables according to GOST 31565 П1б.1.1.2.1.

STRUCTURE

Conductor

Copper, single-wire or multi-wire core, of circular or sector-shaped form, of the 1 or 2 class according to GOST 22483 with the cross-section from 1.5 to 1000mm2

Thermal barrier for CCC (current-carrying conductor)

The lapping with two mica tapes.

Insulation

Of halogen-free polymer composition.

Core arrangement

Insulated conductors of 2, 3, 4 and 5 core cables are twisted in a cable core. Color coded.

Inner sheath

Of halogen-free polymer composition.

Over sheath

Of halogen-free polymer composition.

Number and nominal cross-section of conductors, mm2 Outer diameter, mm Weight of 1km of cable, kg Volume of combustible mass, l/km
PPGng(A)-FRHF 1x1,5 8,5 108 56
m
PPGng(A)-FRHF 1x2,5 8,9 125 60
m
PPGng(A)-FRHF 1x4 9,6 152 68
m
PPGng(A)-FRHF 1x6 10,1 180 73
m
PPGng(A)-FRHF 1x10 11,3 243 89
m
PPGng(A)-FRHF 1x16 12,6 326 105
m
PPGng(A)-FRHF 1x25 14,7 459 135
m
PPGng(A)-FRHF 1x35 15,9 575 149
m
PPGng(A)-FRHF 1x50 17,7 759 178
m
PPGng(A)-FRHF 2x1,5 12,7 242 124
m
PPGng(A)-FRHF 2x2,5 13,5 285 138
m
PPGng(A)-FRHF 2x4 14,8 360 165
m
PPGng(A)-FRHF 2x6 15,8 433 185
m
PPGng(A)-FRHF 2x10 18,3 606 243
m
PPGng(A)-FRHF 2x16 20,3 807 292
m
PPGng(A)-FRHF 2x25 24,8 1204 424
m
PPGng(A)-FRHF 2x35 27,1 1511 492
m
PPGng(A)-FRHF 2x50 30,7 2016 623
m
PPGng(A)-FRHF 3x1,5 13,2 268 131
m
PPGng(A)-FRHF 3x2,5 14,1 322 145
m
PPGng(A)-FRHF 3x4 15,5 413 173
m
PPGng(A)-FRHF 3x6 16,6 504 194
m
PPGng(A)-FRHF 3x10 19,2 718 254
m
PPGng(A)-FRHF 3x16 21,4 974 303
m
PPGng(A)-FRHF 3x25 26,3 1457 437
m
PPGng(A)-FRHF 3x35 28,7 1851 503
m
PPGng(A)-FRHF 3x50 33 2533 658
m
PPGng(A)-FRHF 4x1,5 14,1 302 142
m
PPGng(A)-FRHF 4x2,5 15,1 368 157
m
PPGng(A)-FRHF 4x4 16,7 478 189
m
PPGng(A)-FRHF 4x6 18 590 211
m
PPGng(A)-FRHF 4x10 20,9 852 278
m
PPGng(A)-FRHF 4x16 23,4 1172 331
m
PPGng(A)-FRHF 4x25 28,7 1758 478
m
PPGng(A)-FRHF 4x35 31,9 2287 568
m
PPGng(A)-FRHF 4x50 34,8 2644 668
m
PPGng(A)-FRHF 5x1,5 15,2 334 152
m
PPGng(A)-FRHF 5x2,5 16,3 410 168
m
PPGng(A)-FRHF 5x4 18,1 537 202
m
PPGng(A)-FRHF 5x6 19,4 669 224
m
PPGng(A)-FRHF 5x10 22,7 972 294
m
PPGng(A)-FRHF 5x16 25,7 1360 355
m
PPGng(A)-FRHF 5x25 31,9 2056 517
m
PPGng(A)-FRHF 5x35 35,4 2675 610
m
PPGng(A)-FRHF 5x50 38,7 3307 687
m

Number and nominal cross-section of conductors, mm2

PPGng(A)-FRHF, 1 kV

Outer diameter, mm

Weight of 1km of cable, kg

Volume of combustible mass, l/km

PPGng(A)-FRHF 1x1,5 8,9

118

62

m
PPGng(A)-FRHF 1x2,5 9,3

135

66

m
PPGng(A)-FRHF 1x4 10,2

168

78

m
PPGng(A)-FRHF 1x6 10,7

197

84

m
PPGng(A)-FRHF 1x10 11,5

249

93

m
PPGng(A)-FRHF 1x16 12,8

333

109

m
PPGng(A)-FRHF 1x25 14,9

467

140

m
PPGng(A)-FRHF 1x35 16,1

583

154

m
PPGng(A)-FRHF 1x50 17,9

769

184

m
PPGng(A)-FRHF 1x70 18,6

966

194

m
PPGng(A)-FRHF 1x95 20,6

1250

228

m
PPGng(A)-FRHF 1x120 22,1

1513

250

m
PPGng(A)-FRHF 1x150 24,8

1887

313

m
PPGng(A)-FRHF 1x185 26,8

2274

356

m
PPGng(A)-FRHF 1x240 29,4

2863

412

m
PPGng(A)-FRHF 1x300 32,4

3538

491

m
PPGng(A)-FRHF 1x400 36,3

4613

596

m
PPGng(A)-FRHF 1x500 39,5

5648

677

m
PPGng(A)-FRHF 1x625(630) 43,1

6983

771

m
PPGng(A)-FRHF 1x800 47,3

8695

881

m
PPGng(A)-FRHF 1x1000 51,6

10695

1000

m
PPGng(A)-FRHF 2x1,5 13,5

271

141

m
PPGng(A)-FRHF 2x2,5 14,3

317

157

m
PPGng(A)-FRHF 2x4 16,0

413

196

m
PPGng(A)-FRHF 2x6 17,0

489

218

m
PPGng(A)-FRHF 2x10 18,7

627

255

m
PPGng(A)-FRHF 2x16 20,7

830

306

m
PPGng(A)-FRHF 2x25 25,2

1233

440

m
PPGng(A)-FRHF 2x35 27,5

1542

510

m
PPGng(A)-FRHF 2x50 31,5

2089

665

m
PPGng(A)-FRHF 2x70 33,0

2551

719

m
PPGng(A)-FRHF 2x95 37,4

3349

915

m
PPGng(A)-FRHF 2x120 40,4

4042

1048

m
PPGng(A)-FRHF 2x150 45,4

5064

1319

m
PPGng(A)-FRHF 2x185 49,4

6107

1548

m
PPGng(A)-FRHF 2x240 55,4

7801

1943

m
PPGng(A)-FRHF 3x1,5 14,1

300

150

m
PPGng(A)-FRHF 3x2,5 14,9

356

166

m
PPGng(A)-FRHF 3x4 16,8

470

208

m
PPGng(A)-FRHF 3x6 17,9

565

231

m
PPGng(A)-FRHF 3x10 19,6

741

268

m
PPGng(A)-FRHF 3x16 21,9

1000

318

m
PPGng(A)-FRHF 3x25 26,7

1489

456

m
PPGng(A)-FRHF 3x35 29,1

1885

524

m
PPGng(A)-FRHF 3x50 28,2

2088

414

m
PPGng(A)-FRHF 3x70 30,7

2715

460

m
PPGng(A)-FRHF 3x95 34,8

3625

596

m
PPGng(A)-FRHF 3x120 37,2

4395

646

m
PPGng(A)-FRHF 3x150 40,5

5393

754

m
PPGng(A)-FRHF 3x185 44,9

6646

932

m
PPGng(A)-FRHF 3x240 49,6

8412

1092

m
PPGng(A)-FRHF 3x300 54,5

10391

1296

m
PPGng(A)-FRHF 3x400 61,1

13565

1568

m
PPGng(A)-FRHF 4x1,5 15,1

339

164

m
PPGng(A)-FRHF 4x2,5 16,1

407

181

m
PPGng(A)-FRHF 4x4 18,2

544

229

m
PPGng(A)-FRHF 4x6 19,4

661

254

m
PPGng(A)-FRHF 4x10 21,3

879

294

m
PPGng(A)-FRHF 4x16 24,0

1214

357

m
PPGng(A)-FRHF 4x25 29,2

1795

500

m
PPGng(A)-FRHF 4x35 32,4

2327

593

m
PPGng(A)-FRHF 4x50 31,4

2716

511

m
PPGng(A)-FRHF 4x70 34,8

3592

597

m
PPGng(A)-FRHF 4x95 39,1

4716

724

m
PPGng(A)-FRHF 4x120 42,3

5791

817

m
PPGng(A)-FRHF 4x150 46,5

7160

986

m
PPGng(A)-FRHF 4x185 50,7

8694

1143

m
PPGng(A)-FRHF 4x240 56,9

11160

1421

m
PPGng(A)-FRHF 4x300 62,1

13707

1643

m
PPGng(A)-FRHF 4x400 70,8

18107

2106

m
PPGng(A)-FRHF 5x1,5 16,2

375

177

m
PPGng(A)-FRHF 5x2,5 17,3

453

194

m
PPGng(A)-FRHF 5x4 19,7

609

246

m
PPGng(A)-FRHF 5x6 21,1

746

271

m
PPGng(A)-FRHF 5x10 23,2

1001

312

m
PPGng(A)-FRHF 5x16 26,2

1393

375

m
PPGng(A)-FRHF 5x25 32,4

2096

542

m
PPGng(A)-FRHF 5x35 35,9

2719

637

m
PPGng(A)-FRHF 5x50 34,9

3348

613

m
PPGng(A)-FRHF 5x70 38,3

4397

691

m
PPGng(A)-FRHF 5x95 43,5

5844

872

m
PPGng(A)-FRHF 5x120 47,1

7170

983

m
PPGng(A)-FRHF 5x150 51,5

8823

1156

m
PPGng(A)-FRHF 5x185 56,9

10857

1422

m
PPGng(A)-FRHF 5x240 63,0

13783

1677

m