КПБШвнг(А)-FRLS - (KPBShvng(A)-FRLS) - Russian analogue of NHXBYu Fire Resistance Low Smoke FE180 MICA

KPBShvng(A)-FRLS

Description Add to order

SCOPE AND PURPOSE

The cables are designed for transmission and distribution of electric energy in stationary installations, for installation in cable structures, buildings and underground structures, including flammable and explosive areas, as well as for the power circuits of the equipment that operates in the fire.

The class of fire hazard of the cables according to GOST 31565-2012 П1б.1.2.2.2.

 

TECHNICAL DATA

Nominal voltage, kV: 0,66

Ambient temperature during cable operation, °С: from -50 to +50

Resistant with a relative humidity up to 98% at ambient temperature, degree Celsius: +35

Minimum bending radius of the cables, diameters of the cable: 10

Service life, years, not less: 30

Smoke generation in the test cell: not more than 50 %

Test category on the flame retardance : А

Equivalent toxicity index, g/m3 , more than : 40

Fire resistance cables, min, not less: 180

 

STRUCTURE

Conductor

Copper, single-wire, of the 1 class according to GOST 22483-2012, with the cross-section from 1.5 to 6 mm2.

Thermal barrier

Mica tape winding

Insulation

For cables of types KPvBShvng(A)-FRLS – cross-linked, halogen free polymer composition.

For cables of types KPBShvng(A)-FRLS – thermoplastic, cross-linked, halogen free polymer composition.

Core arrangement and twisting

Number of conductors from 4 to 61.

The insulated conductors are twisted in a cable core.

The cables have a digital and color coded marking of the conductors.

Inner sheath

It is made by extrusion with filling with the halogen free polymer compositions.

Cable armoring

It is laid helically with two steel, galvanized tapes.

It is possible to lay the PET-tapes by winding or longitudinally over the armor.

Cable sheath or jacket

PVC-compound of low fire hazard.

Number and nominal cross-section of conductors (mm2) External diameter of cable, mm Weight, kg
KPBShvng(A)-FRLS 4х1,5 17,3 654
km
KPBShvng(A)-FRLS 5х1,5 18,4 733
km
KPBShvng(A)-FRLS 7х1,5 19,5 824
km
KPBShvng(A)-FRLS 10х1,5 23,2 1135
km
KPBShvng(A)-FRLS 14х1,5 24,9 1305
km
KPBShvng(A)-FRLS 19х1,5 27,1 1539
km
KPBShvng(A)-FRLS 27х1,5 31,4 2028
km
KPBShvng(A)-FRLS 37х1,5 34,9 2489
km
KPBShvng(A)-FRLS 52х1,5 40,1 3253
km
KPBShvng(A)-FRLS 61х1,5 42,3 3614
km
KPBShvng(A)-FRLS 4х2,5 18,3 745
km
KPBShvng(A)-FRLS 5х2,5 19,5 842
km
KPBShvng(A)-FRLS 7х2,5 20,7 959
km
KPBShvng(A)-FRLS 10х2,5 25 1352
km
KPBShvng(A)-FRLS 14х2,5 26,7 1557
km
KPBShvng(A)-FRLS 19х2,5 29,1 1859
km
KPBShvng(A)-FRLS 27х2,5 34,2 2517
km
KPBShvng(A)-FRLS 37х2,5 37,7 3073
km
KPBShvng(A)-FRLS 4х4 19,9 898
km
KPBShvng(A)-FRLS 5х4 21,3 1026
km
KPBShvng(A)-FRLS 7х4 22,7 1185
km
KPBShvng(A)-FRLS 10х4 27,7 1698
km
KPBShvng(A)-FRLS 4х6 21,1 1043
km
KPBShvng(A)-FRLS 5х6 22,7 1202
km
KPBShvng(A)-FRLS 7х6 24,5 1420
km
KPBShvng(A)-FRLS 10х6 29,7 2035
km